Cyber & Resilience - 5 min read - 26 October 2026

FortiSIEM 7.5.0: the tool that watches your logs has a public exploit and a Tuesday-night problem (CVE-2026-106173)

Horizon3.ai published the walkthrough, the Canadian Cyber Centre says it is being exploited, and the fix is a single version bump.

If your security monitoring runs on FortiSIEM 7.5.0, this one belongs at the top of the list. It is a place where an attacker who gets in can do two things at once: run code on the box and read what you have been collecting.

The facts

CVE-2026-106173 is a path traversal in the FortiSIEM gRPC service, rated 9.4 and tracked by Fortinet as FG-IR-26-180. The Hacker News reports that only 7.5.0 is affected, 7.6 is not, and 7.5.1 or later fixes it. Fortinet shipped patches the week before the public write-up on 20 October.

Why a public proof of concept changes the clock

Horizon3.ai published research and a working exploit. By the account in that article, the listener on TCP port 27918 handles a query-result request, and the code builds a file path from a value the caller supplies. Directory-climbing sequences escape the intended folder, and a NUL byte cuts off the filename the server would have appended. The result is an arbitrary file write without logging in.

The example shown overwrites a Redis health-check script that cron runs every 60 seconds. That detail matters because it means code execution does not need a restart, a user click or luck. It arrives within a minute. Horizon3 describes two variants, one that replaces an existing file in place and one that creates a new file.

Exploitation status

The Canadian Centre for Cyber Security updated its advisory to say the flaw is exploited in the wild, citing open-source reporting. I would not wait for a second source. The write-up and a ready-made script are public, and the bug needs no credentials.

What to do

  • Check your version. Anything on 7.5.0 should move to 7.5.1 or later. The article offers no other workaround.
  • Until then, block port 27918 from everything that is not a FortiSIEM collector or supervisor. Collectors only need to reach where they report to.
  • Look at the cron-run scripts and anything under /opt/charting for recent modification times you cannot explain.
  • Check for unexpected files written outside the normal result directory, and for new outbound connections from the supervisor.
  • Remember what the box holds. A SIEM stores credentials for log sources, API tokens and the evidence you would use to investigate an intrusion. If it was reachable and unpatched, rotate those and assume an attacker could have edited the records.

A thought on monitoring platforms

Security tooling often sits in a flat management network and gets patched last, because nobody wants to lose log ingestion. Plan the maintenance window before you need it. If you want help doing that for your own estate, write to sales@halfteck.com.

Explore more resources

Browse our full library of enterprise cloud, software, data and AI content.

View all resources